Human Carbonic Anhydrase IX Quantikine ELISA Kit Summary
货号:DCA900
Assay Type
Solid Phase Sandwich ELISA
Format
96-well strip plate
Assay Length
4.5 hours
Sample Type & Volume Required Per Well
Cell Culture Supernates (100 uL), Serum (100 uL), EDTA Plasma (100 uL), Heparin Plasma (100 uL), Citrate Plasma (100 uL), Urine (100 uL)
Sensitivity
4.39 pg/mL
Assay Range
15.6 - 1,000 pg/mL (Cell Culture Supernates, Serum, EDTA Plasma, Heparin Plasma, Citrate Plasma, Urine)
Specificity
Natural and recombinant human CA9
Cross-reactivity
< 0.5% cross-reactivity observed with available related molecules.< 50% cross-species reactivity observed with species tested.
Interference
No significant interference observed with available related molecules.
Precision
Intra-Assay Precision (Precision within an assay) Three samples of known concentration were tested on one plate to assess intra-assay precision
Inter-Assay Precision (Precision between assays) Three samples of known concentration were tested in separate assays to assess inter-assay precision
Cell Culture Supernates, Serum, EDTA Plasma, Heparin Plasma, Citrate Plasma, Urine
| Intra-Assay Precision | Inter-Assay Precision | |||||
|---|---|---|---|---|---|---|
| Sample | 1 | 2 | 3 | 1 | 2 | 3 |
| n | 20 | 20 | 20 | 40 | 40 | 40 |
| Mean | 166 | 338 | 673 | 166 | 333 | 647 |
| Standard Deviation | 6.36 | 7.19 | 20.5 | 10.5 | 21.6 | 39.7 |
| CV% | 3.8 | 2.1 | 3 | 6.3 | 6.5 | 6.1 |
Recovery
The recovery of CA9 spiked to levels throughout the range of the assay in various matrices was evaluated.
| Sample Type | Average % Recovery | Range % |
|---|---|---|
| Cell Culture Media (n=4) | 110 | 103-114 |
| Citrate Plasma (n=4) | 96 | 89-111 |
| EDTA Plasma (n=4) | 99 | 90-110 |
| Heparin Plasma (n=4) | 97 | 88-112 |
| Serum (n=4) | 97 | 87-106 |
| Urine (n=4) | 101 | 89-114 |
Linearity
To assess the linearity of the assay, samples containing and/or spiked with high concentrations of CA9 were serially diluted with the Calibrator Diluent to produce samples with values within the dynamic range of the assay.