返回 产品中心

Human Angiopoietin-2 Quantikine ELISA Kit

    

Human Angiopoietin-2 Quantikine ELISA Kit Summary

深圳子科生物优势代理美国R&DELISA系列产品试剂盒,价格优势,货期短,欢迎来电咨询0755-33164177!

货号:DANG20

Assay Type
Solid Phase Sandwich ELISA
Format
96-well strip plate
Assay Length
4.5 hours
Sample Type & Volume Required Per Well
Cell Culture Supernates (50 uL), Serum (10 uL), EDTA Plasma (10 uL), Heparin Plasma (10 uL), Saliva (50 uL)
Sensitivity
21.3 pg/mL
Assay Range
46.9 - 3,000 pg/mL (Cell Culture Supernates, Serum, EDTA Plasma, Heparin Plasma, Saliva)
Specificity
Natural and recombinant human Angiopoietin-2
Cross-reactivity
< 0.5% cross-reactivity observed with available related molecules.< 50% cross-species reactivity observed with species tested.
Interference
No significant interference observed with available related molecules.

Product Summary

The Quantikine Human Angiopoietin-2 Immunoassay is a 4.5 hour solid-phase ELISA designed to measure human Angiopoietin-2 in cell culture supernates, serum, plasma, and saliva. It contains NS0-expressed recombinant human Angiopoietin-2 and has been shown to accurately quantitate the recombinant factor. Results obtained using natural human Angiopoietin-2 showed linear curves that were parallel to the standard curves obtained using the Quantikine kit standards. These results indicate that this kit can be used to determine relative mass values for naturally occurring human Angiopoietin-2.

Precision

Intra-Assay Precision (Precision within an assay) Three samples of known concentration were tested on one plate to assess intra-assay precision
Inter-Assay Precision (Precision between assays) Three samples of known concentration were tested in separate assays to assess inter-assay precision

Cell Culture Supernates, Serum, EDTA Plasma, Heparin Plasma, Saliva

Intra-Assay Precision Inter-Assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 40 40 40
Mean 237 703 1301 276 805 1494
Standard Deviation 16.4 45.6 54.4 28.8 73 111
CV% 6.9 6.5 4.2 10.4 9.1 7.4

Recovery

The recovery of Angiopoietin-2 spiked to levels throughout the range of the assay in various matrices was evaluated.

Sample Type Average % Recovery Range %
Cell Culture Media (n=4) 103 98-113
EDTA Plasma (n=4) 95 85-104
Heparin Plasma (n=4) 94 87-104
Serum (n=4) 100 90-107

Linearity

To assess the linearity of the assay, samples containing and/or spiked with high concentrations of Angiopoietin-2 were serially diluted with Calibrator Diluent to produce samples with values within the dynamic range of the assay.
Human Angiopoietin-2 ELISA Linearity