Human M-CSF Quantikine ELISA Kit Summary

Catalog               Size / Price

DMC00B              1 Kit / Please Inquire
SMC00B              1 Pack (6 Plates) / Please Inquire

PDMC00B            1 Pack (50 Plates) / Please Inquire

Assay Length
4.5 hours
Specificity
Natural and recombinant human M-CSF
Cross-reactivity
< 0.5% cross-reactivity observed with available related molecules.< 50% cross-species reactivity observed with species tested.
Interference
No significant interference observed with available related molecules.

Product Summary

The Quantikine Human M-CSF Immunoassay is a 4.5 hour solid phase ELISA designed to measure human M-CSF in cell culture supernates, serum, plasma, saliva, and urine. It contains CHO cell-expressed recombinant human M-CSF and has been shown to accurately quantitate the recombinant factor. Results obtained using natural human M-CSF showed linear curves that were parallel to the standard curves obtained using the Quantikine kit standards. These results indicate that this kit can be used to determine relative mass values for naturally occurring human M-CSF.

Precision

Intra-Assay Precision (Precision within an assay) Three samples of known concentration were tested on one plate to assess intra-assay precision
Inter-Assay Precision (Precision between assays) Three samples of known concentration were tested in separate assays to assess inter-assay precision

Cell Culture Supernates, Saliva, Urine

Intra-Assay Precision Inter-Assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 40 40 40
Mean 248 751 1503 280 827 1620
Standard Deviation 19.4 16.1 49 30.2 76 87.7
CV% 7.8 2.1 3.3 10.7 9.2 5.4

Serum, EDTA Plasma, Heparin Plasma

Intra-Assay Precision Inter-Assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 40 40 40
Mean 357 951 1767 343 1019 1956
Standard Deviation 17.4 24.9 49.4 43.4 84.1 88.8
CV% 4.9 2.6 2.8 12.6 8.3 4.5

Recovery

The recovery of M-CSF spiked to levels throughout the range of the assay in various matrices was evaluated.

Sample Type Average % Recovery Range %
Cell Culture Media (n=4) 99 90-107
EDTA Plasma (n=4) 100 93-106
Heparin Plasma (n=4) 99 93-106
Serum (n=4) 101 96-106

Linearity

To assess the linearity of the assay, samples containing and/or spiked with high concentrations of M-CSF were serially diluted with the appropriate Calibrator Diluent to produce samples with values within the dynamic range of the assay.