返回 产品中心
Human AgRP Quantikine ELISA Kit
深圳子科生物优势代理美国R&DELISA系列产品试剂盒,价格优势,货期短,欢迎来电咨询0755-33164177!
Human AgRP Quantikine ELISA Kit
| Catalog # | Availability | Size / Price | |
|---|---|---|---|
| DAGR00 | Contact your distributor for availability. | 1 Kit / Please Inquire | |
Assay Type
Solid Phase Sandwich ELISA
Format
96-well strip plate
Assay Length
4.5 hours
Sample Type & Volume Required Per Well
Cell Culture Supernates (50 uL), EDTA Plasma (50 uL), Heparin Plasma (50 uL), Urine (25 uL)
Sensitivity
2.68 pg/mL
Assay Range
7.8 - 500 pg/mL (Cell Culture Supernates, EDTA Plasma, Heparin Plasma, Urine)
Specificity
Natural and recombinant human AgRP
Cross-reactivity
Cross-reactivity observed with 1 or more available related molecules.< 50% cross-species reactivity observed with species tested.
Interference
No significant interference observed with available related molecules.
Precision
Intra-Assay Precision (Precision within an assay) Three samples of known concentration were tested on one plate to assess intra-assay precision
Inter-Assay Precision (Precision between assays) Three samples of known concentration were tested in separate assays to assess inter-assay precision
EDTA Plasma, Heparin Plasma
| Intra-Assay Precision | Inter-Assay Precision | |||||
|---|---|---|---|---|---|---|
| Sample | 1 | 2 | 3 | 1 | 2 | 3 |
| n | 20 | 20 | 20 | 40 | 40 | 40 |
| Mean | 56.6 | 144 | 262 | 45.1 | 130 | 246 |
| Standard Deviation | 3.14 | 4.86 | 7.82 | 4.66 | 10 | 18.1 |
| CV% | 5.5 | 3.4 | 3 | 10.3 | 7.7 | 7.4 |
Cell Culture Supernates, Urine
| Intra-Assay Precision | Inter-Assay Precision | |||||
|---|---|---|---|---|---|---|
| Sample | 1 | 2 | 3 | 1 | 2 | 3 |
| n | 20 | 20 | 20 | 40 | 40 | 40 |
| Mean | 54.3 | 143 | 257 | 43.7 | 126 | 238 |
| Standard Deviation | 2.64 | 3.88 | 5.69 | 3.91 | 8.24 | 16.3 |
| CV% | 4.9 | 2.7 | 2.2 | 8.9 | 6.5 | 6.8 |
Recovery
The recovery of AgRP spiked to levels throughout the range of the assay in various matrices was evaluated.
| Sample Type | Average % Recovery | Range % |
|---|---|---|
| Cell Culture Media (n=4) | 106 | 95-115 |
| EDTA Plasma (n=4) | 96 | 89-106 |
| Heparin Plasma (n=4) | 92 | 84-103 |
Linearity
To assess the linearity of the assay, samples containing and/or spiked with high concentrations of AgRP were serially diluted with the appropriate Calibrator Diluent to produce samples with values within the dynamic range of the assay.